High Voltage 40.5kV / 36kV Cast Resin Insulator Contact Box ( Spout )APG Technique

WENZHOU QIUPU ELECTRIC POWER CO., LTD.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

High Voltage 40.5kV / 36kV Cast Resin Insulator Contact Box ( Spout )APG Technique

  • 1
  • 2

Brand Name : QIUPU

Model Number : KYN61

Certification : IEC

Place of Origin : WENZHOU

MOQ : 6PCS

Payment Terms : T/T, Western Union

Supply Ability : 5000PCS/Month

Delivery Time : 7 Days

Packaging Details : Cartons

Material : Casting Resin

Color : Red/Brown

Rate Voltage : 40.5kV /36kV

Frequency Voltage : 98kV

Current : 630A-4000A

Flexural Strength : 10 kN

Creppage Distance : 810mm

Contact Now

CTH-40.5 40.5kV , 36kV Epoxy Resin Casting Resin Insulators ( Spout ) with KYN61 switchgear

The solid seal column uses the APG technique, the automatic pressure gel molding of epoxy resin. It can shorten the production cycle of epoxy insulation from ten hours to ten minutes, and can control exothermic effect well. It can compensate the shrinkage caused by curing reaction, and has excellent dimensional stability and high mechanical strength.

The maximum rated current is only 630A, and the circuit breaker can reach 3000A above(there are more than 4000A in foreign countries). The maximum rated current is only 630A, and the circuit breaker can reach 3000A or above(there are currently more than 4000A in foreign countries). The circuit breaker is usually short-circuit-protected. In case of overload, it takes a certain time(and can not be adjusted unless the internal fuse is replaced) to cut off the hot fuse of the internal fuse of the circuit, and the inner voltage switch is used to protect the overload of the device Or sulphur hexafluoride load switch.

Item Name Rated voltage (KV) Rated frequency(Hz) Frequency withstand voltage 5 min (KV) Local discharge (pc) Creep distance (mm) Dispute bend (kN) Lighting impulse withstand voltage (KV)
1
3 Contactor box (1250A) 12 50 45 ≤10 >240 ≥8 80
4 Contactor box (1600A) 12 50 45 ≤10 >240 ≥8 80
5 Wall bushing (260*395) 40.5 50 98 ≤10 ≥840 ≥10 185

High Voltage 40.5kV / 36kV Cast Resin Insulator Contact Box ( Spout )APG Technique We are specialty on epoxy resin medium voltage and high voltage components, such as 10KV, 24 KV and 40.5KV Circuit Breaker , Load breaker switch , Disconnecting Switch , Epoxy resin switchgear bushing , contactor box , insulators and transformer . 630A, 1250 A ,2500A , 3150A and 4000A contact box , club contact , fix contact, arm contact and jaw contact . 630A and 1250A VS1 circuit breaker . 630A and 1250A ZN85-40.5 circuit breaker . 12KV and 24KV earth switch. KYN28A-12 and KYN61 high voltage switchgear components .


Product Tags:

high voltage bushing

      

high voltage post insulators

      
China High Voltage 40.5kV / 36kV Cast Resin Insulator Contact Box ( Spout )APG Technique wholesale